经皮胸壁心脏起搏(以下简称“经皮起搏”)在紧急抢救心脏停搏时,操作简便快速、可靠且安全有效。在新颁布的JJF1149-2014《心脏除颤器校准规范》中也新增了对经皮起搏功能的检测要求。本文介绍了一种便携式经皮起搏检测装置的设计与实现,对当前相当一部分没有经皮起搏检测能力的除颤器检测装置是一种有益补充。一、装置设计目标与电路设计从JJF1149-2014中可知,经皮起搏检测装置工作
Percutaneous chest wall pacing (hereinafter referred to as “percutaneous pacing”) in the emergency rescue cardiac arrest, the operation is simple, fast, reliable and safe and effective. In the newly promulgated JJF1149-2014 “standard defibrillator” also added a new percutaneous pacing function testing requirements. This article describes the design and implementation of a portable percutaneous pacing detection device, which is a good supplement to the current part of the defibrillator detection device without percutaneous pacing detection capability. First, the device design goals and circuit design From JJF1149-2014 we can see, percutaneous pacing detection device work