对目前常用的混凝土绝热温升公式及其参数取值进行了分析,分别使用不同试验数据与0.8m米厚墙体的实测温度,对目前常用混凝土绝热温升公式及其参数取值的适用性进行了验证,结果表明基于特定试验数据得出的拟合公式与参数取值不具有普遍适用性,直接套用会产生较大误差,并对产生误差的原因进行了分析,说明今后在混凝土绝热温升研究中应注意的问题。
The commonly used concrete adiabatic temperature rise formula and its parameter values are analyzed, respectively, using different test data and 0.8m thick wall of the measured temperature, the commonly used concrete adiabatic temperature rise formula and its applicability of parameter values The results show that the fitting formulas and parameter values obtained based on the specific test data are not universal applicability, direct application will have a greater error, and the reasons for the error is analyzed, indicating that in the future in the concrete adiabatic temperature L should pay attention to the problem of research.