采用不同的应变速率进行拉伸试验,研究了应变速率对TC4合金抗拉强度及拉伸曲线的影响。结果表明,对于TC4合金,其抗拉强度受应变速率影响较为敏感,随应变速率的提高呈现不断增大的趋势,对比GB/T228.1-2010规定的几个应变速率范围,在范围4内浮动时对抗拉强度的影响较范围3更为显著;应变速率的改变也会对拉伸曲线造成影响,由第一速率转变到第二速率时会造成应力突变,第二速率越大,这种突变现象就越明显。通过透射电镜观察了组织中位错的变化情况,并对拉伸速率改变导致拉伸曲线产生应力突变的原因进行了探索。
Tensile tests were conducted at different strain rates, and the effect of strain rate on tensile strength and tensile curve of TC4 alloy was studied. The results show that the tensile strength of TC4 alloy is more sensitive to the strain rate and tends to increase with the increase of strain rate. Compared with several strain rate ranges specified in GB / T228.1-2010, within the range of 4 The effect of floating on tensile strength is more pronounced than in range 3. The change in strain rate also has an effect on the tensile curve. A change in stress from the first rate to the second rate results in a sudden change in stress. The greater the second rate, The more obvious mutation phenomenon. The changes of dislocation in the microstructure were observed by transmission electron microscopy. The reason of the stress mutation in the tensile curve caused by the change of the tensile velocity was explored.