论文部分内容阅读
In order to investigate the regularity of metal magnetic signals of ferromagnetic materials under the effect of applied load, the static tensile test of Q235 steel and 18CrNiWA steel plate specimens were conducted and metal magnetic memory signals of specimens were measured during the test process.The influencing factors of metal magnetic memory signals and the relationship between axial appliedload and signals were analyzed. The fracture and microstructure of the specimens were observed.The results show that the magnetic signals corresponding to the measured points change linearly approximately with increasing axial load.The microstructure of Q235 steel is ferrite and perlite, whereas that of l8CrNiWA steel is bainite and low-carbon martensite.The fracture of these two kinds of specimens is ductile rupture;carbon content of specimen materials and dislocation glide give much contribution to the characterisffcs of magnetic curves.