论文部分内容阅读
Lower hybrid current drive (LHCD) experiments for investigating the interaction between lower hybrid (LH) wave and residual dc electric field were performed in extensive plasma parameter ranges in the HT-7 superconducting tokamak. The experimental results are well fitted to the Kaey-Fisch theory on the efficiency of LH waves energy converted to poloidal magnetic field energy. The fraction of absorbed LH power is about 0.75 for the HT-7 machine, and the upshift of the LH-wave parallel refraction index during LHCD experiments have been derived by the optimizing fitting parameters. The LH wave is also used for the transformer recharging when the plasma current is maintained unchanged. The highest efficiency about 7% has been achieved in HT-7 machine.