推导并分析了干涉图量化对干涉成像光谱仪复原光谱幅值的影响。结果表明,复原光谱幅值的不确定度受量化条件的影响。在确定了干涉图采样点数后,干涉成像光谱仪复原光谱幅值的不确定度与A/D转换器的量化步长成正比;在固定了量化步长后,不确定度随干涉图采样点数的增加而增大;由干涉图量化引起的复原光谱幅值不确定度的大小还与在实际算法中选取的切趾函数形式有关。
The influence of interference graph quantization on the recovery spectral amplitude of interference imaging spectrometer is deduced and analyzed. The results show that the uncertainty of the recovery spectral amplitude is affected by the conditions of quantization. After confirming the number of interferogram sampling points, the uncertainty of the recovery spectral amplitude of the interference imaging spectrometer is directly proportional to the quantization step of the A / D converter. After the quantization step is fixed, the uncertainty is related to the number of sampling points Increases and increases; the magnitude of the amplitude of the restoration spectrum caused by the interference graph quantization is also related to the apodization function form selected in the actual algorithm.