【摘 要】
:
Goodness of fit is demonstrated for theoretical calculation of z-scan data based on beams propagating in the nonlinear medium and the Fresnel–Kirchhoff diffraction integral in experiments with high nonlinear refraction and absorption. The constancy
【机 构】
:
KeyLaboratoryofSpaceAppliedPhysicsandChemistry,MinistryofEducation,andShaanxiKeyLaboratoryofOpticalI
【出 处】
:
ChineseOpticsLetters
论文部分内容阅读
Goodness of fit is demonstrated for theoretical calculation of z-scan data based on beams propagating in the nonlinear medium and the Fresnel–Kirchhoff diffraction integral in experiments with high nonlinear refraction and absorption. The constancy of nonlinear optical parameters is achieved regardless of sample thickness and laser intensity, which clarifies the physical significance of optical parameters. We have obtained = 2.0 × 10?19 m2/W and = 5.0 × 10?13 m/W for carbon disulfide excited by a pulsed laser at 800 nm with pulse duration of 35 fs, which are independent of sample thickness and laser intensity. Affirming constancy of the extracted parameters to the incident light intensity may become a practice to verify the goodness of the z-scan experiment.
其他文献
为提高发光二极管(LED)的光提取效率,分析了光栅形状(矩形、等腰梯形、等腰三角形)对提取效率的影响;基于等效介质理论和严格耦合波法,优化了集成不同形状光栅的LED。利用有限时域差分法,模拟计算了三种不同最优结构LED的光提取效率。研究结果表明,在0.4~0.5 μm波长范围内,等腰三角形光栅倒装LED的光提取效率均在70%以上,最高可达77.75%,而梯形光栅倒装LED的光提取效率最低,最高仅能达到58%。
为减少吸收和散射对生物组织荧光光谱的干扰,使用蒙特卡罗(MC)方法模拟不同光学参数下的生物组织荧光和漫反射光,提出基于组织漫反射光谱的荧光复原方法。将复原算法中的经验参数编码为解空间中的一个粒子,以组织荧光临床应用效果作为适应值,构建粒子群优化(PSO)算法实现经验参数优化。利用已建立的用于糖尿病无创筛查的组织光谱测量系统,收集327例受试者的皮肤组织荧光光谱和漫反射光谱,使用基于PSO的组织荧光复原算法进行光谱复原。以复原前、后的组织荧光光谱强度作为输入变量进行受试者工作特性(ROC)曲线分析,观察其在
本文从理论上和实验上阐明了在偏振内调制激励光谱学中的相位正交特性.当一束线偏振光被偏振调制,而另一束线偏振光的偏振方向固定时,适当调节后一束光的偏振方向,以使多普勒加宽背景与洛仑兹信号的相位正交,可以获得无多普勒的光谱.
据巴黎大学基础电子学研究所的R. Julien和J. M. Lourtioz报告,对波长为117及184微米的CH2F2激光器性能的最佳化,使该激光器在用于高密度等离子体诊断方面变得很有吸引力,以代替波长为195微米的DCN放电型激光器及118.8微米的光抽运甲醇激光器。
报道了激光二极管(LD)侧面抽运Nd:YAG晶体间歇振荡1064 nm和1319 nm双波长激光器。采用间歇振荡技术,可有效地控制上能级的反转粒子数,避免激光振荡谱线之间的双波长竞争效应,而且对输出镜镀膜精度的要求大大降低,稳定的间歇振荡双波长激光输出较容易获得。两声光间的延迟时间连续可调,因此可以通过调节延迟时间来改变双波长激光的输出功率之比。在抽运电流为22 A,声光重复频率为4 kHz,延迟时间为10 μs时获得1319 nm激光偏振输出功率6.2 W,1064 nm激光偏振输出功率5.1 W。根据
A second harmonic generation system with two type II KDP crystals in quadrature is optimized for the nanosecond chirp pulse. The acceptance bandwidth of this optimizing scheme is close to 10 nm by using two crystals with slightly opposite angular detuning
运用一种新的测量单面镀膜膜层光学参数的方法, 对不同热处理的GeTe半导体薄膜样品的光学参数进行了测量, 准确地获得了被测薄膜材料的光学参数, 并采用椭圆偏振光谱测量作比较研究。 以此为基础, 对用椭偏仪测得的数据进行拟合计算, 得出了样品材料在250~830 nm波段范围的复折射率曲线。
报道了高精度激光光束参数(Μ2因子)测量系统的原理、结构和实验结果。该系统以数字化制冷面阵CCD为探测器,具有图像背景扣除、噪声确定、光斑能摄分布二维和三维显示、图像直方图、光束宽度、发散角、M2因子 等光束参数测量等功能, 已用于对多种灯抽运, LD抽运固体激光器光束参数的测量。此外, 还研制了可产生从 TEMo.jlj TEM35.。的多种光场分布的LD抽运固体激光横摸发生器,并对这些模式的M2因子进行了实验测量,测量值的理论值吻合。
红外复杂背景抑制是红外告警等系统发现远距离弱小目标的难题之一。提出了一种将奇异值分解与对偶树复小波变换(DTCWT)相结合的多尺度截断复杂背景抑制新方法。首先采用DTCWT对图像进行正变换,获得图像的多尺度和方向细节特征;然后根据目标和背景杂波信号系数在不同尺度之间的差异,对各子带采用奇异值分解进行处理,并利用最大的特征值重构子带;最后将系数调整后的各子带逆变换到图像域,从而将弱小目标和背景杂波分