,Quantifying lateral penumbra advantages of collimated spot-scanning beam for intensity-modulated pr

来源 :核技术(英文版) | 被引量 : 0次 | 上传用户:areschicken
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Intensity-modulated proton therapy (IMPT) is becoming essential for proton therapy and is under rapid development. However, for IMPT, the lateral penumbra of the spot-scanning proton beam is still an urgent issue to be solved. Patient-specific block collimators (PSBCs), which can block unnecessary doses, play a crucial role in passive scattering delivery technology but are rarely used in spot scanning. One objective of this study is to investigate the lateral penumbra variations of intensity-modulated spot scanning with and without a PSBC. For fields with varying degrees of sharpness and at varying depths in a water phantom, the lateral penumbral widths were calculated using a Monte Carlo-based dose engine from RayStation 6. The results suggest that the lateral penumbral widths can be reduced by more than 30% for uniform target volumes, regardless of whether a range-shifter is used, and that the maximum dose beyond the field edges can be reduced significantly. The results of patient cases show that the doses in organs-at-risk near the edge of the target volume decrease if a PSBC is implemented. This study demon-strates that intensity-modulated spot scanning with a PSBC can effectively reduce the lateral penumbra and block unnecessary doses and is therefore promising for clinical applications in spot-scanning proton therapy.
其他文献
Because of the growing conce over the radia-tion dose delivered to patients, X-ray cone-beam CT (CBCT) imaging of low dose is of great interest. It is dif-ficul
A helium cryogenic system is designed by the Institute of Mode Physics, Chinese Academy of Sci-ences, to supply different cooling powers to the cryomod-ules of
党中央、国务院作出的建设创新型国家的决策,是事关社会主义现代化建设全局的重大战略决策.建设创新型国家,核心就是把增强自主创新能力作为发展科学技术的战略基点,走出中国
NG-CT-10 and NG-CT-20 are newly developed grades of nuclear-grade graphite from China. In this study, their oxidation behaviors were experimentally investigated
The transverse emittance of the extracted beam from the heavy ion medical machine cyclotron is measured and then optimized for injection into the synchrotron. F
A real-time double-ring neutron time-of-flight (TOFII) spectrometer system has been proposed to achieve plasma diagnosis on HL-2M tokamak with a relatively high
The protein complex crystallographic beamline BL19U1 at the Shanghai Synchrotron Radiation Facility is one of the five beamlines dedicated to protein sciences o
Radiochromic film is a useful tool for beam quality assurance, but accurate response assessment of the film is still a problem. In this study, the response unce
This work presents the results of computer simulation of neutronic processes in a high-temperature gas-cooled thorium reactor for 30 different options of core l
The emission angle distribution of projectile fragments (PFs) and the temperature of PF emission sources for fragmentation of 56Fe on polyethylene, carbon, and