THE EVOLUTION OF FIELD DEPLOYABLE fNIR SPECTROSCOPY FROM BENCH TO CLINICAL SETTINGS

来源 :JournalofInnovativeOpticalHealthSciences | 被引量 : 0次 | 上传用户:momoww
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
In the late 1980s and early 1990s, Dr. Britton Chance and his colleagues, using picosecond-long laser pulses, spearheaded the development of time-resolved spectroscopy techniques in an effort to obtain quantitative information about the optical characteristics of the tissue. These efforts by Chance and colleagues expedited the translation of near-infrared spectroscopy (NIRS)-based techniques into a neuroimaging modality for various cognitive studies. Beginning in the early 2000s, Dr. Britton Chance guided and steered the collaboration with the Optical Brain Imaging team at Drexel University toward the development and application of a field deployable continuous wave functional near-infrared spectroscopy (fNIR) system as a means to monitor cognitive functions, particularly during attention and working memory tasks as well as for complex tasks such as war games and air traffic control scenarios performed by healthy volunteers under operational conditions. Further, these collaborative efforts led to various clinical applications, including traumatic brain injury, depth of anesthesia monitoring, pediatric pain assessment, and brain-computer interface in neurology. In this paper, we introduce how these collaborative studies have made fNIR an excellent candidate for specified clinical and research applications, including repeated cortical neuroimaging, bedside or home monitoring, the elicitation of a positive effect, and protocols requiring ecological validity. This paper represents a token of our gratitude to Dr. Britton Chance for his influence and leadership. Through this manuscript we show our appreciation by contributing to his commemoration and through our work we will strive to advance the field of optical brain imaging and promote his legacy.
其他文献
期刊
美帝陆军导弹司令部红石兵工厂研究发展管理处的科学工作者正使用一台178呎(约合60米)长的N-CO2-He激光器。这台巨型激光器的输出功率为2.3千瓦,效率为10%~14%。目前进行的修改完成后,其输出可望增至4.5千瓦,效率为20%~28%。
期刊
期刊
An optical feedback cavity ring-down technique (OF-CRD), in which the retro-reflection of the ring-down cavity (RDC) is re-injected into the oscillator cavity of a Fabry-Perot diode laser and causes the spectral fluctuation of the diode laser, is develope
A broadband instantaneous multi-frequency measurement system based on chirped pulse compression, which potentially has a sub-megahertz (MHz) accuracy and a hundred-gigahertz (GHz) measurement range, is demonstrated. A signal-under-test (SUT) is converted
期刊
由于上一财政年度的经费不能移入次一财政年度使用,美帝军事部门在6月30日1970财政年度结束以前,又匆忙与工业部门签订了几十个激光订货与研制合同,金额约达7,500,000美元。
期刊
利用激光溅射的方法,已经在离子阱中产生并囚禁了C n(n=1~13)原子团簇离子,并取得了溅射产生原子团簇的质量范围随激光脉冲能量的变化以及原子团簇离子的稳定存储随囚禁时间的变化关系等结果。囚禁时间可达20 s。
为提高圆光栅编码器测角精度、满足角秒甚至亚角秒级的精度测量需求,分析了影响其角度测量精度的误差来源,针对性地提出了多读数头读数平均法的补偿方法,进而控制误差源。根据圆光栅测角原理,分析了光栅系统刻化误差、读数头细分误差、光栅安装偏心误差、安装形变误差、轴晃误差等误差来源,从频域的角度分析了各个误差的频谱,根据误差源分析,可采用多读数头读数平均法的补偿方法。实验结果表明,在偏心误差约为15″、光栅形