  Hyphenated techniques such as GC or LC combined with mass spectrometry provide a unique combination of separation and detection power.With its ease-of-use and lower cost, GC/MS and LC/MS with single quadrupole MS have become the workhorse instruments in many areas.Typically operating at unit mass resolution, these instruments have only been able to perform analysis with nominal mass accuracy, not enough for the determination of elemental composition of unknown compounds, which conventionally calls for the more expensive higher resolution MS systems.
其他文献
Traditionally, quantitative measurement of trace chemicals requires a variety of pretreatment methods to enrich target analytes from complicate sample matrix before determinations.These methods are al
Calixarene are macrocyclic molecules, and this kind of stationary phases have high capacity of molecular recognition.We got good separation of six polycyclic aromatic hydrocarbons (PAHs) on calixarene
Three micron hydrophilic interaction liquid chromatography (HILIC) columns, TSKgel Amide-80 3μm were developed for use in glycomic stydies or in LC/MS applications for hydrophilic compounds including
Numerous chemical compounds can form persistent toxic residues in air, soil, water and foods.Pesticides are one of the principal classes of such environmental pollutants which results in serious safet
Three micron ODS columns, TSKgel ODS-100V 3μm were developed for use in LC/MS applications, in particular for the analysis of active pharmaceutical ingredients and their metabolites.The behavior of th
Advanced glycation end products (AGEs) are a heterogeneous group of proteins that have been modified with glucose or carbohydrates adducts, and are thought to be responsible for many complications of
Aqueous size exclusion chromatography is a powerful tool for determining of bio polymers like peptides, proteins and DNAs.TSK-GEL SW series is one of typical aqueous SEC columns for analyzing biologic
A fast and simple method, which involves continuous-flow microextraction (CFME) followed by high-performance liquid chromatography (HPLC) and variable-wavelength detection (VWD), has been developed to
In this paper, a new stationary phase based on 1-allyl,3-methylimidazolium chloride ([AMIM]Cl)ionic liquid were synthesized by vinyltriethoxysilane modified silica and [AMIM]Cl.The capacity factors (k
Superose 12 column, which is filled with the 12% cross-linked agarose gel, is often used to separate and purify high molecular weight compounds.The application of this matrix for isolation and purific
会议