论文部分内容阅读
Based on the finite element model,the local fatigue stress is analyzed at the position of U rib to deck weld connections.Different construction details are considered,including the thickness of the deck,the thickness of U rib,the pavement,whether opening a hole for U rib on the transverse diaphragm or not and how large of the hole.The influences of different construction details to fatigue stress are analyzed and reasonable suggestions for construction details are given.