【摘 要】
:
Objective:To compare the clinic outcome between cervical spine stability reconstruction and vertebral artery adventitia decollement decompression in treating vertebral artery type of cervical spondylo
【机 构】
:
西安交通大学医学院第一医院骨外科,西安,710061,中国
【出 处】
:
2007SICOT国际矫形外科学术会议(SICOT-SIROT SHANGHAI CONGRESS 2007)
论文部分内容阅读
Objective:To compare the clinic outcome between cervical spine stability reconstruction and vertebral artery adventitia decollement decompression in treating vertebral artery type of cervical spondylosis,investigate its main etiological factors and provide a indication for the operation.
其他文献
Objective:To report two cases of microendoscopically assisted anterior screw fixation for the Type Ⅱ odontoid fracture.Methods:Casel(male,58-year-old) and case2(male,47-year-old) were operatively mana
Design:Retrospective evaluation of 257 cases,which had surgical treatment of unstable spinal fractures since 2003.Objective:A new technique for anterior fusion and stabilization in spinal fractures is
Purpose:To discuss the treatment about AF internal fixation positioning and percutaneous reduction by leverage and artificial bone graft for latest thoracic and lumbar vertebrae firacture and its appl
Objective:To evaluate the clinical effect in the treatment of serious bursting fracture in thoracic and lumbar vertebra with AF system by retrospective analyse.Method:All of the cases were treated wit
Objectives:This retrospective study was designed to review the clinical application and outcome of Bryan artificial disc replacement in the treatment of cervical disc disorders (CDD).To investigate th
Objective:To study the neurologic criterion and curative effect facts of cervical spondylotic myelopathy.Methods:A prospective study were carried out and 21 cases of cervical spondylotic myelopathy we
Objective:Compare vertebral body heights of 2 groups after operation.Methods:Dick screw and AF screw were used to treat 52 cases of vertebral fracture and all the patients received follow-up.Result:Be
A good results were achieved in 50 levels in 33 cases with the technique of stability reconstruction with Harms mesh and plate followed cervical corpectomy.Among them,there were 26males and 7 females,
Objective:To analyse the reasons of subsidence of the mesh and to estimate its sequent influence on cervical curve and clinical result after anterior cervical corpectomy reconstruction with titanium m
Objective:Compare the stabilizations between Ti web autoallergic skeletal grain and autoallergic ilium piece in re-establish C-spine anterior part architecture.Methods:Spinal cord typed cervical syndr