论文部分内容阅读
Flow rate and temperature are important parameters for design and operation of liquid lead–bismuth(Pb Bi) experimental loop. The PREKY facility was designed to study test technique of flow rate and local temperature of Pb Bi loop. In this work, flow rate monitoring of molten Pb Bi was performed, and temperatures of the Pb Bi and pipe surface were measured. The results show that the flow rate of the venturi-nozzle flow meter had an uncertainty of ±5 % in the range of 0.6–2.0 m/s, and the maximum temperature difference between the Pb Bi and pipe surface was about 8 ℃.
Flow rate and temperature are important parameters for design and operation of liquid lead-bismuth (Pb Bi) experimental loop. The PREKY facility was designed to study test technique of flow rate and local temperature of Pb Bi loop. In this work, flow rate monitoring of molten Pb Bi was performed, and temperatures of the Pb Bi and pipe surface were measured. The results show that the flow rate of the venturi-nozzle flow meter had an uncertainty of ± 5% in the range of 0.6-2.0 m / s , and the maximum temperature difference between Pb Bi and pipe surface was about 8 ° C.