作业六区集气站分离器、甲醇罐、污水灌区大部分使用翻柱式浮子液位计。近年来,该类型液位计出现了浮球腐蚀穿孔、浮筒腐蚀结垢、顶杆下端锁销腐蚀断裂、磁性面板与浮球对应转换失灵等故障,此类问题在不同程度上影响集气站正常生产,结合现场实际运行选用磁致伸缩式液位计在该区南10站现场试验,应用效果表明磁致伸缩式液位计具有安装简单、故障率低、计量准确和经济效益明显等优点,可以推广到其它集气站投入使用。
Six gas station gas station separator, methanol tank, most of the sewage irrigated column-type float level gauge. In recent years, this type of liquid level gauge has appeared floating ball corrosion perforation, buoy corrosion scale, the lower end of the mandrel corrosion cracking, magnetic panel and float conversion failure corresponding failure, such problems affect gas gathering stations to varying degrees Normal production, combined with the actual operation of the site selection of magnetostrictive level gauge in the South 10 stations in the field test results show that magnetostrictive liquid level gauge with simple installation, low failure rate, accurate measurement and obvious economic benefits , Can be extended to other gas station put into use.