论文部分内容阅读
目的了解常州市武进区各级医疗机构的消毒灭菌工作现状及工作质量,发现消毒管理工作中存在的问题,有针对性地提出改进措施。方法对全区各级医疗机构消毒质量进行采样监测。结果 2年共采样2 991份,合格2 882份,平均总合格率为96.4%。不同监测项目中,压力蒸汽灭菌器灭菌效果、使用中消毒液、医疗用品和物体表面合格率较高,分别为100.0%、99.8%、99.4%和98.4%;其次是医护人员手、紫外线灯和内窥镜,合格率分别为96.8%、93.5%和90.0%;室内空气合格率最低,为85.8%。结论 2010-2011年该区各级医疗机构消毒质量一直保持较高的水平,但室内空气合格率偏低,应引起重视,进一步采取改进措施。
Objective To understand the current situation and quality of disinfection and sterilization work of medical institutions at all levels in Wujin District of Changzhou City and to find out the problems existing in the disinfection and management work and propose the improvement measures in a targeted manner. Methods Sampling and monitoring the disinfection quality of medical institutions at all levels in the district. The results of 2 years a total of 2 991 samples, 2 882 qualified, with an average total passing rate of 96.4%. Among the different monitoring items, the sterilizing effect of the pressure steam sterilizer, the disinfectant solution, the medical products and the surface of the objects in use have a high pass rate of 100.0%, 99.8%, 99.4% and 98.4% respectively; followed by the hand of medical staff, ultraviolet Lamps and endoscopes, the pass rates were 96.8%, 93.5% and 90.0% respectively; the lowest passing rate of indoor air was 85.8%. Conclusion From 2010 to 2011, the disinfection quality of medical institutions at all levels in the district has been maintained at a high level, but the pass rate of indoor air is low, which should be taken seriously and further improvement measures taken.