1故障现象2012年3月10日,高原HXD1C型3001号机车在西宁—格尔木间做型式试验时报辅助变流器(简称ACU1)均压电阻故障,将机车控制电源断开复位后,机车运行15 min左右继续报该故障,在隔离ACU1后,机车继续运行。2处理过程机车回段后,在检修库内模拟故障。升弓闭合主断路器后测量ACU1模拟信号入出板10A(SV7)、10B(SV8)和14B(中间电压),发现10A、10B孔电压从3.3V开始逐渐下降,电压下降到2.6V后(1 V对应电容电压100 V,电容正常均压330V),机车主断路器自动断开,同时上报“ACU1
1 Fault phenomenon March 10, 2012, Plateau HXD1C 3001 locomotive in Xining - Golmud to do type test Times Auxiliary Converter (ACU1) equalizing resistance fault, the locomotive control power disconnect and reset, locomotive operation 15 min continue to report the fault, after the isolation ACU1, the locomotive to continue running. 2 processing locomotive back to the paragraph, in the overhaul library simulation failure. After the closing of the main circuit breaker, the ACU1 analog signal was measured to reach 10A (SV7), 10B (SV8) and 14B (intermediate voltage). The voltage of 10A and 10B holes decreased gradually from 3.3V, V corresponds to the capacitor voltage 100 V, the capacitor normal voltage 330V), locomotive main circuit breaker automatically disconnect, at the same time reported ”ACU1