论文部分内容阅读
摘要:随着城市环境规划建设发展,各种施工技术随之大力发展。尤其是曲线顶管施工,以不需开挖面层就可以穿越地面以及各种地下障碍优势,被城市建设中广泛使用。曲线顶管施工中要先测量再放中心线,之后再开挖以及测量标高等,因此在整个施工中测量监理占据了重要因素,也是确保曲线顶管施工关键因素。本文就是从某市政建设中曲线顶管检测监理實况入手,总结了测量监理主要方法与任务,并在此基础上加强施工控制要点,进而规范施工要求和设计。
关键词:测量监理;曲线顶管;城市工程
Abstract: With the development of the urban environment planning and construction, the various construction techniques along with actively developed. Curve top tube construction can pass through the ground, they do not require excavation surface layer as well as a variety of underground obstacles advantages, widely used in urban construction. The first measurement came alive again in the center line of the curved pipe jacking construction after excavation and measuring elevation measurements in the entire construction supervision occupy an important factor, but also ensure that the key factors of curved pipe jacking construction. This article is from a municipal building in the curve of the top tube detection Supervision live paper summarizes the main method of measurement supervision and task, and on this basis to strengthen the construction control points, and thus regulate the construction requirements and design.
Keywords: Measuring supervision; curve top tube; city of engineering
中图分类号:K826.16 文献标识码:A 文章编号:
1 前言
近些年以来,城市化建设进程在不断加速,顶管施工技术的应用越来越广泛。而顶管施工通常是在地下进行施工,必然会受到各种不可预见的因素影响,加之这种技术施工比较复杂,施工中常会导致管道的中线发生高程超标,进而出现较大误差,一旦控制不到位就会影响到工程进度和质量,甚至还可能发生事故。因此监理怎样才能够依据相应行为准则而合理监督、评价、监控以及约束测量工程至关重要,这是测量监理必须处理的问题。
2 测量监理的作用
在探究城市曲线顶管施工中测量监理之前,首先就要掌握测量监理存在的价值和作用,只有在这个基础上研究曲线顶管施工测量监理才具有真正价值。总体来看,测量监理具有如下一些作用。
(1)控制质量
测量主要是确定底物空间的位置,通过科学测量构建控制网将各个地方数据按照相同精度合理联系起来。测量中就是通过施工放样来控制质量。假如不能够正确保障测量放线,再好构想也仅仅是一个图形,而不能够将这种构想变为现实。在城市工程中挖的再快但是没挖对还需要填上,洞打的无论多标准都只能作废。为了不发生错误性施工,城市工程都要先进行测量,确保正确施工方向,同时也是控制质量的最有效最基层的手段。
(2)控制投资
在城市工程施工中挖土石方是施工中一个较大项目,同时也是工程量较大的项目,因此准确计量直接关系着整体投资的控制。过去依靠估堆、查车或者招标之时采用数值计算,导致承建单位(投资方)和施工单位(具体施工方)心中没底,而且缺乏科学计量手段必然致使双方都不能够拿出有效数据来证明。但是开工之前联合测量原始地形,必然降低了双方争执。而测量监理全面细致掌握了设计图纸,具备了计算机绘图及处理能力,能够有效监控审核土石开挖、喷护及回填等各种工程量的计算,降低了发生重复劳动几率。
3城市曲线顶管施工中的测量监理
3.1 工程概况
为了研究测量监理在曲线顶管施工之中的应用,本文就以某市政工程作为案例进行探析。某市政工程就是对某河坊街实施改造,所设计的路段长度为55米,宽度为12米,和原路宽度比较相近,该工程要同步铺设配套的管线,按照设计要求雨水管径为D2000,埋深为3.7——5.0米,污水管道直径D1500,埋深为4.0——6.0米,两管的净距为0.890米,都是使用了钢筋混凝土管。
3.2 顶管施工测量监理
(1)施工前测量监理的准备
其一,监理单位一旦接收到了相关设计图纸之后,就要组织相关人员仔细分析图纸,并且要组织设计进行交底,相关设计人员就要给各个管线施工企业以及监理人员交底,阐述设计的意图与施工要求。测量监理员就要仔细聆听意图和要求并充分进行领会,在该基础上合理制定测量监理的工作计划,以及实施测量监理的细则,同时还要到城市工程项目覆盖的范围中去布置控制点,一切按照相关技术要求执行,这样才能够确保有效控制及管理工程质量,也只有完全掌握了设计意图才能够抓住工程的关键环节与部位,实施监理智能。同时测量监理一旦发现问题就应该及时需找原因并采取有效措施解决,如果有必要还要通知设计人员,防止影响施工进度和质量。
(2)开工之前进行交接桩
要注意收集工程中测量高级控制点所测量出来的基准数据资料,具体应该由承建单位安排勘测单位给监理工程师进行交桩,组号是交接全线的平面控制桩,具体包括了导线桩、方向桩、转角桩以及洞涵定位桩等等,还涉及到高程控制桩以及控制桩的护桩。交桩之时一定要及时了解与收集各种数据,要确保各种平面与高程之间的连接关系及精度。如果整个工程是2个以上的施工单位施工,就要检查各个标段结合部的桩位连接关系情况,一旦重要桩位缺失太多,就要勘察单位进行补桩。
3.3 复测测量控制
一旦完成准备工作之后,监理测量单位就要认真对测量方案进行审查、检查和检测施工导线的测量计算等,对各种勘察点实施复测,确保施工放样与测量成果符合要求。
3.3.1 复测平面的控制点
一般来说曲线顶管项目工程中,平面控制点、线型布置大都是依照附合导线进行布设,随着引入全站仪及GPS等测量手段,有效提升了测量导线的精确度。同时顶管施工中的定位精度逐渐提高,提升了测量的精确度。在本案例工程中顶管施工中因精度低而出现碰头与擦边现象。
附合导线的方位角闭合差可以用公式计算:该式中α起是导线起算的方位角;β左是推算路线的前进方向朝着左传递角;而n且是传递角的个数。
按照误差传递定律,就取了两倍误差当做限差,进而就能够求出导线方位角的闭合差误差:。而本文所先的工程中误差就小于了,将这值带到上式就有方位角的闭合差为:。
3.3.2 复测高程控制点
在曲线顶管工程中的高程控制大都是按照线路水准来设置成附合水准线路,基准就是在勘测所提供点位基础中,布设成临时水准点与永久性的水准点。因此必须要按照相关规定复测计算方法,将标段中水准点联测到同一个水准路线中,往返复测高差是不能够低于,其中L表示单程水准路线的长度。
3.4 施工中的测量监理
对于曲线顶管项目来说,距离不同导致各种测量监理要求也存在侧重差异,但都要求具备质保体系,还要及时进行检查,将测量放样、质量控制作为监理工作之重点。事实上,测量基本等同于曲线顶管的眼睛。
本文案例工程中的曲线顶管工程,承建单位会同设计监理、质监及其他施工部门按照相关章程执行,顶管允许的偏差如下表:
表1 顶管允许的偏差(mm)
曲线顶管施工是依靠平面与高程控制系统来确保,因此施工阶段的测量功能是沉井构造物进行定位放样及施工顶进,所以监理就应该监督施工企业遵从整体到局部测量原则。而且该测量属于细致工作,要满足精度,反之且会给曲线顶管工程埋下质量隐患,尤其要复测井底、管底的标高,并且要定期复测顶管施工的用水准点,防止控制点发生变化出现返工现象。
在施工之中如因开挖回填及一些路线的中边桩被破坏,就应该去施工企业将中线桩恢复,桩位之间要按照20米作为间隔设置点,而曲线段要每隔10米布设一个点。而且IP点原则上要使用坐标法进行放样,如果遇到挡土墙就要预留挡土墙位置,如果属于道路的交叉口红线交点就必须要依次放出。同时在施工中要时常检查各种策略标志,一旦发现遗失或者移动过大就要及时进行校正,还要定期检查各种测量仪器的精度,尤其是水准仪i角必须要依据实况每周检查1次。
为了确保高程传递的精度,当从地面朝着井下传递两个水准点之时,就要使用两次仪器实施观测,不同仪器的水准点高程差值不能够超过5mm。在井下和地面各自安装水准仪与水准尺测量三次。作为测量监理,必须要注意下面几个方面的问题:
(1)精确测定曲线顶管的轴线、控制好井中心的平面定位;
(2)测量施工水准上要控制曲线顶管高程;
(3)安装顶进设备及架设测量,要注意基坑定位于放样,同时还要严格检查基坑模板的尺寸,如果有条件最好是使用坐标法进行放样,确保建立顶进设备的正确位置,确保基坑建筑满足检测要求。
3.5 工程计量中的测量监理
计量监理是控制工程投资的基础,而且有效测量手段能够实现实际工程量。计量支付不但是管理合同金额的重要环节,还是控制合同总体目标主要手段,如果不抓住这个环节测量监理都将流于形式。测量监理计量测量之原则是,其一要符合合同规定计量支付项目;其二要依据计划图纸规定要求实施项目;其三就是要质量检验符合规范要求项目。因此測量监理就应该适用实地测量,控制原始的地面线及各个结构层的分界面,进而控制好工程量的计量。在测量监理中监理人员要确保测量与计量具备科学、准确、公正以及可靠。
4 结束语
总而言之,城市曲线顶管施工测量监理不但要实施工程测量,还要依据控制施工质量、控制进度与投资,同时要组织协调展示监理的自身作用。因此要做好测量监理,就要遵循科学、公正公平准则基础上维护单位权益,确保施工企业的合法性。以较高专业知识及较高综合素质能力,在城市曲线顶管施工中发挥巨大作用。
参考文献:
[1]姜宏艳.刘勇浅谈地下顶管施工测量[J]-.黑龙江交通科技,2010,33(2)
[2]舒亚明.周永江.SHU Ya-ming.ZHOU Yong-jiang .长距离曲线顶管测量和控制[J].浙江工业大学学报,2009,37(6)
[3]郭如卫.浅论曲线顶管的关键技术控制[J].中国高新技术企业,2007(13)
[4]李明.Li Ming.大口径长距离蛇行曲线顶管的施工技术[J].城市道桥与防洪,2007(9)
[5]徐朝晖.郑全兴.长距离大口径钢管顶管施工质量控制[J].山西建筑,2009,35(32)
[6]李凤梧.浅谈大口径超长距离钢顶管施工顶力控制[J].山西建筑,2010,36(7)
关键词:测量监理;曲线顶管;城市工程
Abstract: With the development of the urban environment planning and construction, the various construction techniques along with actively developed. Curve top tube construction can pass through the ground, they do not require excavation surface layer as well as a variety of underground obstacles advantages, widely used in urban construction. The first measurement came alive again in the center line of the curved pipe jacking construction after excavation and measuring elevation measurements in the entire construction supervision occupy an important factor, but also ensure that the key factors of curved pipe jacking construction. This article is from a municipal building in the curve of the top tube detection Supervision live paper summarizes the main method of measurement supervision and task, and on this basis to strengthen the construction control points, and thus regulate the construction requirements and design.
Keywords: Measuring supervision; curve top tube; city of engineering
中图分类号:K826.16 文献标识码:A 文章编号:
1 前言
近些年以来,城市化建设进程在不断加速,顶管施工技术的应用越来越广泛。而顶管施工通常是在地下进行施工,必然会受到各种不可预见的因素影响,加之这种技术施工比较复杂,施工中常会导致管道的中线发生高程超标,进而出现较大误差,一旦控制不到位就会影响到工程进度和质量,甚至还可能发生事故。因此监理怎样才能够依据相应行为准则而合理监督、评价、监控以及约束测量工程至关重要,这是测量监理必须处理的问题。
2 测量监理的作用
在探究城市曲线顶管施工中测量监理之前,首先就要掌握测量监理存在的价值和作用,只有在这个基础上研究曲线顶管施工测量监理才具有真正价值。总体来看,测量监理具有如下一些作用。
(1)控制质量
测量主要是确定底物空间的位置,通过科学测量构建控制网将各个地方数据按照相同精度合理联系起来。测量中就是通过施工放样来控制质量。假如不能够正确保障测量放线,再好构想也仅仅是一个图形,而不能够将这种构想变为现实。在城市工程中挖的再快但是没挖对还需要填上,洞打的无论多标准都只能作废。为了不发生错误性施工,城市工程都要先进行测量,确保正确施工方向,同时也是控制质量的最有效最基层的手段。
(2)控制投资
在城市工程施工中挖土石方是施工中一个较大项目,同时也是工程量较大的项目,因此准确计量直接关系着整体投资的控制。过去依靠估堆、查车或者招标之时采用数值计算,导致承建单位(投资方)和施工单位(具体施工方)心中没底,而且缺乏科学计量手段必然致使双方都不能够拿出有效数据来证明。但是开工之前联合测量原始地形,必然降低了双方争执。而测量监理全面细致掌握了设计图纸,具备了计算机绘图及处理能力,能够有效监控审核土石开挖、喷护及回填等各种工程量的计算,降低了发生重复劳动几率。
3城市曲线顶管施工中的测量监理
3.1 工程概况
为了研究测量监理在曲线顶管施工之中的应用,本文就以某市政工程作为案例进行探析。某市政工程就是对某河坊街实施改造,所设计的路段长度为55米,宽度为12米,和原路宽度比较相近,该工程要同步铺设配套的管线,按照设计要求雨水管径为D2000,埋深为3.7——5.0米,污水管道直径D1500,埋深为4.0——6.0米,两管的净距为0.890米,都是使用了钢筋混凝土管。
3.2 顶管施工测量监理
(1)施工前测量监理的准备
其一,监理单位一旦接收到了相关设计图纸之后,就要组织相关人员仔细分析图纸,并且要组织设计进行交底,相关设计人员就要给各个管线施工企业以及监理人员交底,阐述设计的意图与施工要求。测量监理员就要仔细聆听意图和要求并充分进行领会,在该基础上合理制定测量监理的工作计划,以及实施测量监理的细则,同时还要到城市工程项目覆盖的范围中去布置控制点,一切按照相关技术要求执行,这样才能够确保有效控制及管理工程质量,也只有完全掌握了设计意图才能够抓住工程的关键环节与部位,实施监理智能。同时测量监理一旦发现问题就应该及时需找原因并采取有效措施解决,如果有必要还要通知设计人员,防止影响施工进度和质量。
(2)开工之前进行交接桩
要注意收集工程中测量高级控制点所测量出来的基准数据资料,具体应该由承建单位安排勘测单位给监理工程师进行交桩,组号是交接全线的平面控制桩,具体包括了导线桩、方向桩、转角桩以及洞涵定位桩等等,还涉及到高程控制桩以及控制桩的护桩。交桩之时一定要及时了解与收集各种数据,要确保各种平面与高程之间的连接关系及精度。如果整个工程是2个以上的施工单位施工,就要检查各个标段结合部的桩位连接关系情况,一旦重要桩位缺失太多,就要勘察单位进行补桩。
3.3 复测测量控制
一旦完成准备工作之后,监理测量单位就要认真对测量方案进行审查、检查和检测施工导线的测量计算等,对各种勘察点实施复测,确保施工放样与测量成果符合要求。
3.3.1 复测平面的控制点
一般来说曲线顶管项目工程中,平面控制点、线型布置大都是依照附合导线进行布设,随着引入全站仪及GPS等测量手段,有效提升了测量导线的精确度。同时顶管施工中的定位精度逐渐提高,提升了测量的精确度。在本案例工程中顶管施工中因精度低而出现碰头与擦边现象。
附合导线的方位角闭合差可以用公式计算:该式中α起是导线起算的方位角;β左是推算路线的前进方向朝着左传递角;而n且是传递角的个数。
按照误差传递定律,就取了两倍误差当做限差,进而就能够求出导线方位角的闭合差误差:。而本文所先的工程中误差就小于了,将这值带到上式就有方位角的闭合差为:。
3.3.2 复测高程控制点
在曲线顶管工程中的高程控制大都是按照线路水准来设置成附合水准线路,基准就是在勘测所提供点位基础中,布设成临时水准点与永久性的水准点。因此必须要按照相关规定复测计算方法,将标段中水准点联测到同一个水准路线中,往返复测高差是不能够低于,其中L表示单程水准路线的长度。
3.4 施工中的测量监理
对于曲线顶管项目来说,距离不同导致各种测量监理要求也存在侧重差异,但都要求具备质保体系,还要及时进行检查,将测量放样、质量控制作为监理工作之重点。事实上,测量基本等同于曲线顶管的眼睛。
本文案例工程中的曲线顶管工程,承建单位会同设计监理、质监及其他施工部门按照相关章程执行,顶管允许的偏差如下表:
表1 顶管允许的偏差(mm)
曲线顶管施工是依靠平面与高程控制系统来确保,因此施工阶段的测量功能是沉井构造物进行定位放样及施工顶进,所以监理就应该监督施工企业遵从整体到局部测量原则。而且该测量属于细致工作,要满足精度,反之且会给曲线顶管工程埋下质量隐患,尤其要复测井底、管底的标高,并且要定期复测顶管施工的用水准点,防止控制点发生变化出现返工现象。
在施工之中如因开挖回填及一些路线的中边桩被破坏,就应该去施工企业将中线桩恢复,桩位之间要按照20米作为间隔设置点,而曲线段要每隔10米布设一个点。而且IP点原则上要使用坐标法进行放样,如果遇到挡土墙就要预留挡土墙位置,如果属于道路的交叉口红线交点就必须要依次放出。同时在施工中要时常检查各种策略标志,一旦发现遗失或者移动过大就要及时进行校正,还要定期检查各种测量仪器的精度,尤其是水准仪i角必须要依据实况每周检查1次。
为了确保高程传递的精度,当从地面朝着井下传递两个水准点之时,就要使用两次仪器实施观测,不同仪器的水准点高程差值不能够超过5mm。在井下和地面各自安装水准仪与水准尺测量三次。作为测量监理,必须要注意下面几个方面的问题:
(1)精确测定曲线顶管的轴线、控制好井中心的平面定位;
(2)测量施工水准上要控制曲线顶管高程;
(3)安装顶进设备及架设测量,要注意基坑定位于放样,同时还要严格检查基坑模板的尺寸,如果有条件最好是使用坐标法进行放样,确保建立顶进设备的正确位置,确保基坑建筑满足检测要求。
3.5 工程计量中的测量监理
计量监理是控制工程投资的基础,而且有效测量手段能够实现实际工程量。计量支付不但是管理合同金额的重要环节,还是控制合同总体目标主要手段,如果不抓住这个环节测量监理都将流于形式。测量监理计量测量之原则是,其一要符合合同规定计量支付项目;其二要依据计划图纸规定要求实施项目;其三就是要质量检验符合规范要求项目。因此測量监理就应该适用实地测量,控制原始的地面线及各个结构层的分界面,进而控制好工程量的计量。在测量监理中监理人员要确保测量与计量具备科学、准确、公正以及可靠。
4 结束语
总而言之,城市曲线顶管施工测量监理不但要实施工程测量,还要依据控制施工质量、控制进度与投资,同时要组织协调展示监理的自身作用。因此要做好测量监理,就要遵循科学、公正公平准则基础上维护单位权益,确保施工企业的合法性。以较高专业知识及较高综合素质能力,在城市曲线顶管施工中发挥巨大作用。
参考文献:
[1]姜宏艳.刘勇浅谈地下顶管施工测量[J]-.黑龙江交通科技,2010,33(2)
[2]舒亚明.周永江.SHU Ya-ming.ZHOU Yong-jiang .长距离曲线顶管测量和控制[J].浙江工业大学学报,2009,37(6)
[3]郭如卫.浅论曲线顶管的关键技术控制[J].中国高新技术企业,2007(13)
[4]李明.Li Ming.大口径长距离蛇行曲线顶管的施工技术[J].城市道桥与防洪,2007(9)
[5]徐朝晖.郑全兴.长距离大口径钢管顶管施工质量控制[J].山西建筑,2009,35(32)
[6]李凤梧.浅谈大口径超长距离钢顶管施工顶力控制[J].山西建筑,2010,36(7)