  This study investigated methods for improving the performance of heat exchangers for use in the hot-water supply side of a heat-pump-type water heater system.The pressure drop and heat transfer characteristics inside the coiled flow channel of corrugated tubes in laminar and turbulent flow regions were experimentally investigated.Four corrugated copper tubes with an outside diameter of 12.7 mm and coiled diameters of 100,120,140,and 180 mm were used in this experiment.
其他文献
A standard is a document that provides requirements,specifications,guidelines or characteristics that can be used consistently to ensure that materials,products,processes and services are fit for thei
会议
This study employs the particle swarm optimization algorithm to determine the optimum operation of each refrigerant compressor unit within the refrigeration system to obtain the most energy-saving ope
会议
This study investigates the heat and mass transfer performance of the dehumidification system under periodic change of environmental pressure by simulation.Based on some available literatures,in order
会议
Permanent magnet(PM)motors which are operated by the variable frequency drive have the superior efficiency to traditional induction motors(IMs).Therefore,PM motors have been widely adopted in the indu
会议
Chiller is among the most power consuming equipment in a centralized air conditioning system.It provides chilled water for comfort cooling in buildings and manufacturing processes in a factory.In Taiw
会议
This article presents the energy saving retrofit implements and operating analysis of the HVAC system in ITRI biomedical factory.The system adopts heat pump rather than electrical heater to provide ho
会议
This simulation study aims at the energy and condensation analysis of chilled beam system in the office building in Taiwan,where is in hot and humid climate.EnergyPlus simulation program is used in th
会议
The present study has been carried out to analyze the heat transfer characteristics of gaskets in the mullion region of frost-free refrigerator/freezer.A 3D numerical model for the mullion region betw
会议
A 200RT centrifugal refrigerant compressor had been totally designed and analyzed.The objectives of the design are high efficiencies at full load and partial load conditions.The design procedure inclu