New acoustic system for continuous measurement of river discharge and water temperature

来源 :Water Science and Engineering | 被引量 : 0次 | 上传用户:yxrlxggd
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
In many cases,river discharge is indirectly estimated from water level or streamflow velocity near the water surface.However,these methods have limited applicability.In this study,an innovative system,the fluvial acoustic tomography system(FATS),was used for continuous discharge measurement.Transducers with a central frequency of 30 kHz were installed diagonally across the river.The system’s significant functions include accurate measurement of the travel time of the transmission signal using a GPS clock and the attainment of a high signal-to-noise ratio as a result of modulation of the signal by the 10th order M-sequence.In addition,FATS is small and lightweight,and its power consumption is low.Operating in unsteady streamflow,FATS successfully measured the cross-sectional average velocity.The agreement between FATS and acoustic Doppler current profilers(ADCPs) on water discharge was satisfactory.Moreover,the temporal variation of the cross-sectional average temperature deduced from the sound speed of FATS was similar to that measured by a temperature sensor near the bank. In many cases, river discharge is indirectly estimated from water level or streamflow velocity near the water surface. Here, these methods have limited applicability. In this study, an innovative system, the fluvial acoustic tomography system (FATS), was used for continuous discharge measurement. Transducers with a central frequency of 30 kHz were installed diagonally across the river. The system’s significant functions include accurate measurement of the travel time of the transmission signal using a GPS clock and the attainment of a high signal-to-noise ratio as a result of modulation of the signal by the 10th order M-sequence. FATS is small and lightweight, and its power consumption is low. Operating in unsteady streamflow, FATS successfully measured the cross-sectional average velocity. acoustic Doppler current profilers (ADCPs) on water discharge was satisfactory. Moreover, the temporal variation of the cross-sectional average temperature deduced from t he sound speed of FATS was similar to that measured by a temperature sensor near the bank.
其他文献
本文介绍了黄河大河家水电站工程坝顶2×2000/630kN双向门机主要机构的设计特点。为节约布置空间,对主、副两套起升机构共用一个小车进行了多个方案的比较分析。两套起升机构
本文介绍了一种新型混凝土保温砖,它在生产过程中实现了混凝土多孔砖与EPS板的一次成型.通过EPS板与混凝土燕尾连接及内部设置钢丝连接,使承重区、保温区、保护层三者牢固地
近年来,随着国内旅游业的快速发展和大众休闲娱乐意识的增强,旅游演艺产品的市场需求增长迅速.因旅游演艺在丰富景区及旅游地的文化内涵、提升旅游地形象,提高旅游地收益,以
本文通过对建设广西制浆造纸重点实验室的紧迫性,介绍现有实验室的现状以及构建具有广西特色的制浆造纸重点实验室提出对策与建议.通过建设广西制浆造纸重点实验室,可以更好
文章试以ABC工程公司为例,通过将管理会计在项目管理中的灵活运用,使得各项风险控制,成本控制与企业管理紧密结合起来,提升其整体核心竞争能力,以达到项目综合效益最大化的目
随着IP业务的快速增长,对网络宽带的需求不仅变得越来越大,并且由于IP业务量本身的不确定性和不可预见性,多网络带宽的动态分配要求也越来越迫切,单靠传统的人工配置网络连接
阐述了发电厂汽轮机旁路系统的功能、形式,归纳了国内部分百万千瓦超超临界机组运行方式不同的旁路系统功能和容量,便于同类后续工程选择合适的旁路系统.
动态贝叶斯网能很好地处理随时间变化多变量问题,基于动态贝叶斯网的状态预测模型可以较准确地描述系统状态和影响因素之间的关系.本文利用推理宽度来简少推理过程的数据量,
目的探讨不同治疗方式对浸润深度局限于胆囊壁内的T1、T2期胆囊癌预后的影响。方法对浸润深度局限于胆囊壁内的45例T1和T2期胆囊癌患者的预后进行回顾分析。结果Cox多因素分
目的 了解发展为明确自身免疫性疾病的未分化结缔组织病(UCTD)的临床特点.方法 随机选取1105份住院病例,其中系统性红斑狼疮(SLE)751例、系统性硬化症(SSc)63例、多发性肌炎/