1台发电机组上配置了1台新的6135型柴油机。该柴油机冷态机油压力为0.4MPa,但是温度上升到40℃时机油压力仅有0.1MPa,由此导致该发电机组不能正常工作。该故障排查过程如下:首先对机油滤清器处的调压阀进行调整,试机后无效,更换机油滤清器总成及调压阀仍无效;其次拆下油底壳,捡查机油泵接口,并更换1个新机油泵,故障依旧;最后对该柴油机进行仔细捡查,发现曲轴轴向间隙为2mm,比技术规范0.13~0.37mm大了许多,由此初步判定机油压
A generator set is equipped with a new 6135 diesel engine. The diesel engine oil pressure is cold 0.4MPa, but the temperature rises to 40 ℃ when the oil pressure is only 0.1MPa, resulting in the genset can not work properly. The troubleshooting process is as follows: First of all, the oil filter at the regulator to adjust the test machine is invalid, the replacement of the oil filter assembly and the pressure regulator is still invalid; followed by removal of the oil pan, pick up the oil pump Interface, and replace a new oil pump, the fault still; Finally, the diesel engine carefully picked up and found crankshaft axial clearance of 2mm, 0.13 ~ 0.37mm larger than the technical specifications, which initially determine the machine oil pressure