24小时脑电实时记录仪,应用于癲痫及脑梗塞、脑外伤等50例检测与EEG对比分析,结果在临床确诊为癲痫发作13例中,动态脑电图(AEEG)呈痫样放电11例,检出率为84.62%,与EEG 1例检出看样放电(7.69%)相比,P<0.01’有高度显著差异。在可疑癫痫18例病例中,AEEG痫样放电14例,检出率为77.78%,与EEG 3例中检主病样放电(16.7%)相比,P<0.01,有高度显著差异。AEEG比EEG更易发现痫样放电,提高癫痫之诊断,与国外报导相近似。观察中其额,中颞部痫样放电较多,与文献报导一致。
24 hours EEG real-time recorder, used in epilepsy and cerebral infarction, traumatic brain injury and other 50 tests and EEG comparative analysis, the results of clinically diagnosed seizures in 13 cases, dynamic electroencephalography (AEEG) showed epileptiform discharge In 11 cases, the detection rate was 84.62%. There was a highly significant difference at P <0.01 compared with one case of EEG (7.69%). In 18 cases of suspected epilepsy, 14 cases of AEEG epileptiform discharge were detected, the detection rate was 77.78%, which was highly significant compared with that of 3 cases of EEG (16.7%), P <0.01. AEEG is more likely to find epileptiform discharge than EEG and improve the diagnosis of epilepsy, similar to foreign reports. Observed in the amount of epileptiform discharge more, consistent with the literature.