论文部分内容阅读
This study investigated the degradation of bisphenoI-A (BPA) by ultrasonic irradiation in the presence of different additives (H2O2, air bubbles and hic acid) under various operating conditions, i.e., ultrasonic frequency, power intensity and power density. The results demonstrated that the BPA degradation followed pseudo first-order kinetics under different experimental conditions. The optimum power intensities were 0.9, 1.8, and 3.0 W/cm2 at the frequencies of 400, 670, and 800 kHz, respectively. At the fixed frequency (800 kHz), the degradation rate of BPA was shown proportional to the increase of power density applied. With this manner, the BPA sonolysis could be facilitated at H2O2 dosage being lower than 0.1 mmol/L; while BPA degradation was hindered at H2O2 concentration in excess of I mmol/L. Additionally, BPA removal was shown to be inhibited by the presence of aeration and humic acid during ultrasonic irradiation. The present study suggested that the degradation rate of BPA assisted by ultrasonic irradiation was influenced by a variety of factors, and high BPA removal rate could be achieved under appropriate conditions.