晶体旋转法是测量液晶分子预倾角的常用方法,但不适用于测量20°~70°之间的预倾角。提出一种棱镜辅助晶体旋转法测量预倾角的方案。把液晶盒夹在两个直角棱镜间,入射光从前面棱镜一个面入射,经过液晶盒从后面棱镜出射,改变入射光的入射角,测量出射光透过率,能得到对应双折射相位差为零、透射光强最大的入射角,进而由几何光学关系确定预倾角。数值模拟和实验结果显示该方法具有可行性。
The crystal rotation method is a common method for measuring the pretilt angle of liquid crystal molecules, but it is not suitable for measuring the pretilt angle between 20 ° and 70 °. Proposed a prism assisted crystal rotation method to measure pretilt. The liquid crystal cell is sandwiched between two right-angle prisms. The incident light is incident on one face of the front prism, and emerges from the rear prism through the liquid crystal cell to change the incident angle of the incident light. The transmittance of the outgoing light is measured, and the phase difference corresponding to birefringence Zero, the maximum incident light transmission angle, and then determine the geometric optical pre-tilt angle. Numerical simulation and experimental results show that this method is feasible.