个人剂量计的种类甚多,上海地区主要采用氟化锂片状个人剂量计,而天津用的是粉剂管状氟化锂个人剂量计,为摸索两种剂量计监测结果是否相符,1990年6月至7月卫生部委托天津与上海地区对个人剂量计作一双轨比较,我区承担了临床诊断X线工作人员的个人剂量双轨比较。一、调查方法1.对象选择:地段医院放射工作人员40名。2.监测方法:个人剂量计均经过标准刻度,两种剂量计放入直径约2厘米的圆形盒内,按个人剂量计佩戴要求,将剂量计佩戴在工作人员的左胸或左衣领处,佩戴周期为一个月。
There are many types of personal dosimeters. In Shanghai, the personal lithium-iodide personal dosimeter is mainly used. In Tianjin, powdery tubular lithium fluoride personal dosimeters are used. To find out whether the two dosimeters are in compliance with the monitoring results, June 1990 July to July the Ministry of Health commissioned in Tianjin and Shanghai personal dosimeter for a double-track comparison, our district to undertake a clinical trial of X-ray staff personal dose comparison. First, the survey method 1 object selection: Lot hospital radiation staff 40. 2. Monitoring methods: Personal dosimeters have been through the standard scale, the two dosimeters into a circular box about 2 cm in diameter, according to personal dosimeter wear requirements, the dosimeter worn on the staff’s left chest or left collar Department, the wear cycle of one month.