在高温下对钢梁与H型钢柱和未填充或部分外包混凝土的连接节点进行一系列试验。对两种钢柱的槽钢连接和部分外包H型钢柱的平端板连接进行研究。试验旨在调查火灾情况下受约束力和大旋转作用影响的梁柱节点的性能,并为研发和验证基于组件的简化连接模型提供试验数据。研究发现,槽钢连接节点具有更高的强度和延性,可以有效地降低节点断裂的概率,从而提高建筑物在火灾情况下的鲁棒性。
A series of tests were conducted at high temperatures on the joints of steel beams with H-beam columns and unfilled or partially overcladded concrete. The connection of the two kinds of steel columns and the connection of the flat-plate with some H-beams were studied. The objective of the experiment was to investigate the behavior of beam-column joints affected by binding and large rotation in a fire situation and to provide experimental data for the development and verification of a simplified component-based connection model. It is found that the joint of channel has higher strength and ductility, which can effectively reduce the probability of node fracture and improve the robustness of the building in case of fire.