论文部分内容阅读
作者在有晶体的近视眼眼内植入前房型玻璃透镜以矫正近视。随访18~36个月,认为手术是成功的。共植入23只眼。眼内透镜视部玻璃屈光指数为1.62,袢为聚酰亚胺,固定穹隆为6°,弦径为12.5~13.5mm不等,角膜横径则比透镜弦径少1mm,有12只限植入透镜屈光度为-8.0D,6只眼为-10.0D和5只眼为-13.0D。患者年龄最小18岁,最大72岁。
The author implants anterior chamber glass lenses in the intraocular lens with myopia to correct myopia. Follow-up 18 ~ 36 months, that surgery is successful. A total of 23 eyes were implanted. The intraocular lens has a refractive index of 1.62 for glass, 聚 polyimide, a fixed dome of 6 °, and a chord diameter of 12.5 to 13.5 mm. The transverse diameter of the cornea is 1 mm less than the lens string diameter and 12 only The refractive power of the implanted lens was -8.0D, the value of -10.0D for 6 eyes and -13.0D for 5 eyes. The youngest patient is 18 years old and the oldest is 72 years old.