目的探讨种植体螺距对骨界面应力分布的影响,为种植体的设计与临床选择提供生物力学的依据。方法采用三维有限元分析法对螺距分别为1.5mm,1.0mm的种植体在受水平向、垂直向力时骨界面应力分布进行分析讨论。结果在水平和垂直向加载条件下,螺距为1.0mm的种植体骨界面应力小于螺距为1.5mm者,应力分布趋于均匀。结论螺纹底部形态为凹面的种植体,螺距1.0mm和1.5mm者应力无明显差别;螺纹底部形态为平面的种植体,螺距1.0mm者应力小于螺距1.5mm者,应力分布更均匀,可做为临床设计和选择种植体的参考。
Objective To investigate the influence of implant pitch on the stress distribution in the bone interface and provide biomechanics basis for the design and clinical choice of implants. Methods Three-dimensional finite element analysis was used to analyze and discuss the stress distribution on the bone interface when the implants were 1.5mm and 1.0mm respectively under horizontal and vertical force. Results Under the condition of horizontal and vertical loading, the stress of the implant bone interface with the pitch of 1.0mm was less than the one with the pitch of 1.5mm, and the stress distribution tended to be uniform. Conclusions There is no obvious difference in the stress between 1.0mm and 1.5mm pitch thread at the bottom of screw thread. The bottom of the screw thread is flat implant. The stress at the pitch of 1.0mm is less than that of the pitch of 1.5mm, and the stress distribution is more uniform Clinical Design and Selection of Implant References.