Background The complicated anatomy of the cervical spine and the variation among pedicles reduces the accuracy and increases the risk of neurovascular complications associated with screw implantation in this region. In this study, we compared the accuracy of cervical (C2-C7) pedicle screw fixation assisted by X-ray fluoroscopy, computed tomography (CT)-based navigation, or intraoperative three-dimensional (3D) C-arm navigation.Methods This prospective cohort study was performed in 82 consecutive patients who underwent cervical pedicle screw fixation. The accuracy of screw insertion was assessed by postoperative CT scan with 3D reconstruction. The accuracy of screw insertion was assessed as: excellent (screw completely within pedicle); acceptable (≤ 1 mm screw outside pedicle cortex); poor (>1 mm screw outside pedicle cortex).Results A total of 145 screws were inserted in 24 patients who underwent C-arm fluoroscopy. Of these, 96 screws (66.2%) were excellent, 37 (25.5%) were acceptable, and 12 (8.3%) were poor. One hundred and fifty-nine screws were inserted in 29 patients in the CT-based navigation group. Among these, 141 (88.7%) were excellent, 14 (8.8%) were acceptable, and 4 (2.5%) were poor. A total of 140 screws were inserted in 29 patients in the intraoperative 3D C-arm navigation group, of which 127 (90.7%) were excellent, and 13 (9.3%) were acceptable. No severe or permanent neurovascular complications associated with screw insertion were observed in any patient.Conclusione CT-based and intraoperative 3D C-arm navigation were similarly accurate, and were both significantly more accurate than C-arm fluoroscopy for guiding cervical pedicle screw fixation. They were able to accurately guide the angle and depth of screw placement using visual 3D images. These two techniques are therefore preferable for high-risk cervical pedicle screw fixation. The ease and convenience of intraoperative 3D C-arm navigation suggests that it may replace virtual-fluoroscopy and CT-based navigation systems in future clinical applications.
其他文献
在图10中,与E分量有关的量子效率和平均内部强度Φ_(in)是利用MTL模型在同样的p、t_a和t_g(但侧面角为48°)条件下计算出来的,波纹上覆盖着介质层和金属层,它们的t_d为0.4μm
目的 建立一种高效液相色谱法,测定替硝唑,戊酸雌二醇复方栓剂中二种组分的含量,用于制剂质量控制.方法 采用反相高效液相色谱法,色谱柱:Kramasil C18柱(150 mm×4.6 mm;5um)
目的 探索微量注射法以不同转基因载体转基因至损伤肌腱的转基因效率、分布和组织反应.方法 用微量注射器将10μl携带增强绿色荧光蛋白(enhanced green fluorescent pro-tein,EGFP)报告基因的pCMV-EGFP、pCAGGS-EGFP、AAV2-EGFP和Ad5-EGFP载体直接注射入鸡的损伤并缝合的趾深屈肌腱.在术后第3,7,14,21天分别取肌腱,进行冰冻切片后
Background Increasing the successful puncture rate of the percutaneous vertebroplasty (PVP) in thoracic vertebral compression fracture by unilateral puncture is
期刊
10月31日,作为上海视觉艺术学院建校十周年庆的系列动,“溯源”——全国设计教育学术研讨会暨2015年中国高等教育学会设计教育专业委员会年会在上海成功举办。  本届会议的主题为“溯源”,旨在全面反思中国设计教育发展历程,探讨社会“新常态—下的设计教育与创新,推动中国设计教育改革不断向前发展。当今中国设计教育,已经发展到近2000所高校、100余个硕士学位授予点、10多个博士学位授予点、近200多万
11月7日,全国工业设计教育研讨会暨第十一届世界华人设计论坛在湖南大学国家超级计算长沙中心举行。100多位海内外设计专家学者、200多位来自全国各地设计院校和产业界的代表汇聚长沙,以设计教育作为出发点,从设计的本源、理念、工具和方法等层面展开全方位交流与思考。  设计学科的技术基础和社会需求正在发生着巨大的转变,设计越来越多的以创新的形式介入到更多的产业和社会公共服务以及人们的日常生活。设计的内涵