论文部分内容阅读
杭州华星电冰箱厂产 BYD-155D 双门双温电冰箱一台,因灌注保温层聚氨酯泡沫时,不慎将冷藏室蒸发器排水管堵塞约3cm,造成箱内积水过多,以致无法正常使用。以上故障经三家修理,均未排除。送我室后,先以0.3~0.4MPa 氮气上下冲吹无效,后用φ0.8mm钢丝自排水管探查亦无效,只排出少量微粒聚氨酯泡沫。分析原因为,聚氨酯泡沫发泡固化后,与排水管内壁呈紧密粘合状。所以,使用气吹法,因受到水管耐压所限,不能压很高的气压。若以硬物探查,由于
Hangzhou Huaxing Refrigerator Factory BYD-155D two-door dual-temperature refrigerator, due to infusion of polyurethane foam, accidentally the refrigerator compartment evaporator drain plug about 3cm, resulting in excessive water box, which can not be normal use. The above three failures by the repair, are not ruled out. Send my room, the first 0.3 ~ 0.4MPa nitrogen up and down blowing ineffective, after using φ0.8mm wire from the drain exploration is also invalid, only a small amount of particulate polyurethane foam. Analysis of reasons is that polyurethane foam foam curing, and drainage pipe wall was closely bonded. Therefore, the use of gas blowing method, due to the water pressure limit, can not be high pressure pressure. If hard to explore, due