我们应用肇庆地区第一人民医院的“血气分析模拟诊断系统”软件对317例病人血气数据进行处理后,共获得了1056条诊断,经两名以上专职医生讨论通过了1050条诊断,6条诊断有争议,诊断正确率达95%以上,未发现错诊及漏诊现象。其中有55条诊断因输入数据不足(没有输入电解质或时间数据),计算机同时输出了两种可能的诊断,在这种情况下,若补足数据则可纠正诊断。 从317例病人血气数据中,随机抽出150例数据交由数名临床医生,让他们在不知道计算机及专职医生诊断的情况下,独立地作出分析报告,与计算机诊断
We used the First People’s Hospital of Zhaoqing City, “blood gas analysis simulation diagnostic software” 317 cases of patients with blood gas data were processed, a total of 1056 diagnosed, after more than two full-time doctors discussed and approved 1050, 6 diagnostic Controversial, correct diagnosis rate of 95% or more, did not find the wrong diagnosis and missed diagnosis. There are 55 diagnoses due to insufficient input data (no input electrolyte or time data), the computer also outputs two possible diagnoses, in which case, if the data can be corrected to correct the diagnosis. From 317 patients’ blood gas data, 150 patients were randomly selected to be referred to several clinicians for independent analysis report without computer and full-time doctor’s diagnosis, and computerized diagnosis