目的了解基层中心卫生院消毒供应室医院感染管理现状及存在问题,提出管理对策。方法通过现场查看和采样检测方法,对本县6所中心卫生院消毒供应室管理情况及质量进行了调查。结果 6所卫生院中有5所设有消毒供应室,但均存在建筑布局不合理,使用后医疗器械清洗不彻底,未开展生物监测。医疗器械灭菌均采用下排气式压力蒸汽灭菌器,少数单位灭菌器存在故障。结论基层中心卫生院消毒供应室从硬件建设到软件管理都不同程度存在问题,需要加强管理,消除医院感染管理的隐患。
Objective To understand the current status and existing problems of hospital infection management in disinfection and supply rooms in primary health centers and to put forward management strategies. Methods Through field inspection and sampling and testing methods, the management and quality of disinfection and supply rooms in 6 central hospitals in this county were investigated. Results Of the 6 hospitals, 5 were equipped with disinfection supply rooms. However, there were irrational architectural layouts, incomplete cleaning of medical equipment after use, and no biological monitoring. Sterilization of medical equipment are used under the exhaust steam sterilizer, a few units sterilizer fault. Conclusion There are some problems in the disinfection supply room of primary-level central hospital from hardware construction to software management, which requires strengthening management and eliminating the hidden dangers of hospital infection management.