论文部分内容阅读
故障现象HP 8200 AW工作站启动失败。故障检修HP 8200的工作站启动后报硬盘数据丢失,可进入应用软件界面,但无任何病例数据。BIOS检测中能认出3个SCSI硬盘,可看到3个硬盘信息。(1)首先怀疑是软件问题。LFC后系统运行到加载RAID卡时出错系统认为RAID卡配置改变,建议重新配置,系统无法启动。(2)对比正常系统检查BIOS的配置,发现均为正常设置。(3)检查发现此系统数据盘的SCSI接线在RAID卡上,而正常的系统应
Symptom HP 8200 AW workstation failed to start. Troubleshooting HP 8200 workstations reported after the hard drive data loss, can enter the application interface, but no case data. BIOS detection can recognize three SCSI hard drives, you can see the three hard drive information. (1) First suspect is a software problem. LFC system to run to load a RAID card error system that the RAID card configuration changes, it is recommended to re-configure, the system fails to start. (2) Compare the normal system to check the BIOS configuration, found that are normal settings. (3) Check that the system data disk SCSI cable in the RAID card, and the normal system should