我院自1982年~1986年3月应用超声波治疗心肌梗塞:急性24例,陈旧性10例,小结如下。设备及具体实施方法机器选用洛阳医用电子仪器厂生产的LY—Ⅱ型超声波治疗机。该机属于低频超声,频率为800千赫/秒,声功率从0.5W/cm~2开始,每档增加0.25W/cm~2,直至2.5W/cm~2。该研究选用0.75~1.75W/cm~2,每5~7天升档一次,每次操作20分钟。接触剂:用液体石腊与凡士林2∶1混合
My hospital from 1982 to March 1986 application of ultrasonic treatment of myocardial infarction: acute 24 cases, 10 cases of old, the following summary. Equipment and specific methods of implementation of machine selection Luoyang Medical Electronic Instrument Factory production of LY-Ⅱ-type ultrasonic treatment machine. The machine belongs to the low-frequency ultrasound, the frequency of 800 kHz / s, the sound power from 0.5W / cm ~ 2 start, each file increase 0.25W / cm ~ 2, until 2.5W / cm ~ 2. The study selected 0.75 ~ 1.75W / cm ~ 2, uplift every 5 to 7 days, each operation for 20 minutes. Contact agent: Mix with liquid paraffin and petrolatum 2: 1