文章介绍了后浇带的分类和功能,论述了高层住宅、公共建筑及主裙楼等结构的现浇混凝土结构后浇带的设计与施工,并提出一些应注意的问题,以供今后的工程实践参考。1后浇带的分类开(1)收缩后浇带,为防止混凝土凝结收缩开裂而设置的后浇施浇工带。建(2)沉降后浇带,为解决高层建筑主楼与裙房的沉降差而设置封的后浇施工带。(3)温度后浇带,为防止混凝土因温度变化拉裂而设置的后浇施工带。混
The paper introduces the classification and function of post-pouring tape, discusses the design and construction of post-pouring tape for cast-in-place concrete structure of high-rise residential buildings, public buildings and main podium, and puts forward some problems that should be paid attention to for future projects Practice reference. 1 after pouring with the classification of open (1) Shrinkage after pouring tape, in order to prevent condensation of concrete shrinkage and set the post-cast construction work zone. Construction (2) pouring zone after settlement, in order to solve the settlement between the main building and the podium of high-rise buildings and set the closure after pouring construction zone. (3) pouring temperature after the tape, in order to prevent the concrete from cracking due to temperature changes and post-pouring construction zone. mix