论文部分内容阅读
卧式高压蒸汽灭菌器也叫高压消毒器,是利用高压蒸汽进行灭菌的器械。它是一个双层密闭容器,夹层和灭菌室各有一压力表。两表工作正常时,所指示的压力数值应相等。当灭菌室的压力增加,温度计指示数也随着增加。笔者在维修时发现,消毒器的两只压力表升到1.4公斤/厘米~2,甚至升到1.5公斤/厘米~2,而温度计指示的温度在118°~120°之间,而在灭菌室放了一只留点温度计,消毒完毕取出温
Horizontal high-pressure steam sterilizer, also known as high-pressure sterilizer, is the use of high-pressure steam sterilization equipment. It is a double sealed container with a pressure gauge on each of the mezzanine and the sterilization chamber. When the two meters are working properly, the indicated pressure values should be equal. As the pressure in the sterilization chamber increases, the thermometer indicator also increases. The author found during repair, the two pressure gauge sterilizer rose to 1.4 kg / cm ~ 2, or even rose to 1.5 kg / cm ~ 2, while the temperature indicated by the thermometer between 118 ° ~ 120 °, Room put a leave a thermometer, remove the temperature finished disinfection